58190

ELECTRICIAN at CAPARROS ELECTRICITE SARL PEYRUIS FRANTA

  • România, Botoșani
  • România, Botoșani
  • Romania, Botoșani
  • Romania, Botoșani
Deblocheaza date contact
Traduceri ale CV-ului
30%
  • Ultima actualizare: 6 mai.
  • Numar referinta: 58190

Limbi straine

Engleza
Mediu
Franceza
Mediu
Italiana
Incepator
Rusa
Incepator
Romana
Nativ
80%
  • Last update: 6 mai.
  • Reference number: 58190

Experience

  • June 2012 - December 2012

    ELECTRICIAN, CAPARROS ELECTRICITE SARL PEYRUIS FRANTA

    • Botoșani, Romania
    • Full time
    • Work domain - Technicians: Construction

    : I  made  cable  routes  and  related  changes   I  pulled  cables  in  various  sizes , for  lighting  room  and  annexes  3g1,5, for  sockets    phase  and  three  phase  3g2,5 , 5j2,5 , 3g6 , 5g6 , for  motion  sensor  , presence  sensor , light  sensor 5g1,5 , for  roof , blinds  5g1,5 , 4g6 , 4g10 . I  pulled  cables  for  alimentation  panels  , generator  included  connections . I  made  links  doses  , sheets  assembling  equipment  and  machinery .  All  these  works  performed  made  by  site  plans  and  wiring  diagrams . I  mounted  switches simple, double , head  scale, in  panels  mounted  breakers  6A ,10A ,16A,32A,100A  , I  did  connection  in  strip  4mm , 6mm ,10mm.I  mounted  transformer  220-24 V  for  auctioned  louvers ,connected  cables  from  generator,  mounted  sockets  phase  , three  phase ,  tv  , energy  telecom.I  pulled  cables  for  lighting  outside  5g1,5 , 3g1,5  mounted  doses i  did  connection ,mounted  lamps  outside. I  fed  drive  sliding  doors  and  windows  smoke  5g1,5m 3g1,5,  5g1 .I  mounted  buttons  fire  signal ,buttons  warning  patients ,  lamps  emergency.  Wiring  diagrams  formed  the  basis  of  all  execution .

  • June 2011 - February 2012

    ELECTRICIAN, CASPIAN MARINE SERVICES ATYRAU KAZAKHSTAN

    • Botoșani, Romania
    • Full time
    • Work domain - Engineering: Energy / Extractive Industries

    : I   mounted  device  and  cables  inside  and  outside  module [detector  gas , smoke , heat  , call point  emergency ] .I  made  change  cables  and  connected  in  panels  system  UPS , CONTROL  ROOM , ENGENEERING  ROOM . I   pulled  cables  force ,  fibre  optique  , telecom ,  change  cable tray  for  new  routes , I  pulled  cables  inside  and  outside  in  various  sizes  CRANE  LIEBHERR .  I  mounted  device  for  protection -  detector  gas  ,  smoke  , heat,  call point  emergency . I  made  panch list  in  room  HEATHER  SYSTEM  , GENERATOR  ,  STATION  COMAND .All  these  works  were  performed  made  by  site  plans  and  wiring diagrams .I  executed  works  in  instrumentation , checking  equipment , replacement  of  defective  alyor  us  after , scheme  installation  location  ,temperature  sensor ,  pressure  sensor , gauge  glass  ,  flow , water  meters ,  gas  meters . I  connected  the  local  boards ,  general  boards  all  devices  and  were  made  functional  evidence . I  pulled  cables  from  devices  3g1, 3g0,75, 5g1 ,5g0,75 , 10g1, 20g1 .  I  mounted  support  and  parabolic  antenna  , I  pulled  cables  in  distribution  panels .
    
    

  • February 2011 - May 2011

    ELECTRICIAN, TCPI PORTUGAL RAFINERY SINES

    • Botoșani, Romania
    • Full time
    • Work domain - Engineering: Energy / Extractive Industries

    I  pulled  cables  .in  various  sizes  for  lighting ,  sockets ,  and  instrumentation  device [ 3g1,5 ,3g2,5 , 5g1,5 , 5g2,5 , 3g6  , 5g1 ,  10g1 ,19g1 ]. I  made  construction  cable tray ,  mounted  doses ,mounted  lamps of  lighting,  sockets phase  and  three  phase  in  various  power ,mounted  device  fop  instrumentation .I  mounted  lamps  emergency ,  button  stop  local  command ,  buttons  of  signal  fire  .All  these  works   were  performed  made  by  site  plans  and  wiring  diagrams. I  mounted  breakers  with  protection ,  sockets  with  protection , buttons  signal  fire ,  lamps lighting  outside  with  protection  , local  buttons  starting-stop  for  electric  motors .For  construction  routes  cable  use  cable tray  50mm ,100mm ,200mm ,300mm,400mm .For  instrumentation  I  mounted  devices ,  flow , gauge  glass ,  pressure  switch ,thermostats , freezing  probe .All  connections I  made  in  local  panels  and  wiring  diagrams  underlying  connections  of  electrical  panels.
    
    

  • February 2010 - December 2010

    ELECTRICIAN, SIMETI ENGENEERING ST. GHISLAIN BELGIUM

    • Botoșani, Romania
    • Full time
    • Work domain - Technicians: Construction

    ; All  the  company  I  worked    in  the  port  of  ANTWERP  on a  new  fleet  of  tanks  for  oil , I  executed  works  in  electric  power  and  instrumentation .I  build  routes  cable  from  diverse  sizes,  power  and  instrumentation  cables   50mm , 100mm , 200mm, 300mm , 400mm , 500mm . I  pulled  cables  from  alimentation  motors  0,75kW , 1,1kW ,4kW, 7kW, 11kW100kW , 250kW  , was  used  for  earthing  conductor  2,5mm , 4mm , 5mm , 10mm .Earthing  from  devices  instrumentation used  1,5mm ,2,5mm .I  mounted  devices  SIEMENS  from  installation ; pressure  switch ,sensor  of  temperature ,  valves ,  solenoid , flow ,pressure  control  valves ,  gauge  glass .These  devices  used  cables  3g0,75 , 3g1, 5g1 , 10g1 . I  mounted  the  discharge berths  signaling  lamps ,  local  sockets ,lighting  lamps .I   made  connection  in  local  panels. I  pulled  cables  for  icing  resistance ,  device  itself  ,cables  connected  in  panels .I   mounted  lighting  lamps  ,  security  lamps ,  pulled  cables  for  alimentation  inside  , outside  park , above  the  tank ,mounted  warning  horn  sound .All  these   works  were  performed  made  by  site  plans  and  wiring  diagrams .
    
    

  • February 2008 - November 2009

    ELECTRICIAN, I&G ELECTRICAL SERVICES NICOSIA CYPRUS

    • Botoșani, Romania
    • Full time
    • Work domain - Technicians: Construction

    This  firm  work  by  device  SIEMENS  , from  construction  panels  electric  have  destination  pump  station , metallurgy ,metro  station .I  selected  after  cod  device  [switch , contactor signaling  lamps   ,  relays  to  temp ].  I  installed  cabling  for  force ,  command  after  wiring  diagrams ,and  there  have  been  probe  of  tension .After  testing  panels  were  packed  for  destination  QATAR , IRAQ , OMAN. Work  are  executed  in  the  production  hall and  panels  from  various  location  intern  le  mounted  and  included  connection .The  wiring  switchboards  selected  by  color  red, brown , blue  voltage  220V , 380V , black , gray , white  control  voltage  12V , 24V, and  after  driving  force   section  2,5mm , 4mm , 6mm , 10mm , and  order  0,75mm , 1mm , 1,5mm . The  installation  of  electrical  panels  for  internal  location  where  we  move  to  fix  the  electrical  panel , pull  cables  and  connect  them  to  strip  after  its  wiring  diagrams .

  • April 2007 - December 2007

    ELECTRICIAN, FASE FORLI ITALY

    • Botoșani, Romania
    • Full time
    • Work domain - Technicians: Construction

    Work performed  This  job  was  different  the  electrical  field  was   new , or  installing  solar  panels . First  operation  was  preparing   solar  panels , and  was  dropping  them  directly  on  metal  or  wood  frame  building   smaller  , respecting  the  minimal   distance   between  panels . After  this  operation  was  completed  , by  connected   solar  panels  scheme  and  the  areas   were  connected   to  the  local    electrical  panels . Following  operation  was  pulling  cables   3g6 , 3g10 , 3g16 , 3g35  connected  one  end  zone  in  switchboards  and  the  other   end   general  inverter  board .All   these  were  possible  because  building  cable  routes    50mm , 100mm , 200mm , 400mm . Painting  connections  were  made  with  pin  4mm , 6mm , 10mm  and  lugs  connection   inverter  board . I  pulled   grounding  end  operations   at  regional  switchboards  and  general  inverter  board.

  • August 1987 - December 2006

    ELECTRICIAN, IRE-CET BOTOSANI, SC ELCO SA BOTOSANI , SC LOIAL SRL SUCEAVA , SC SOMMERING INSTALL BUCHAREST

    • Botoșani, Romania
    • Full time
    • Work domain - Technicians: Construction

    In  the  period  1987-2003 I  worked  as  personal  staff , personal  inspections  and  repairs  IRE-CET  BOTOSANI .Here  we  monitored  electrical  installations  in  power  stations 6kV ,0,4Kv  respectively  in  power  plants ,  lighting  and  control . I  intervened  in  the  case  of  targeting  of  or  damages  to  the  electric  motors , transformer  6-0,4 kV   and  generator  3MW .  All  these  operations  included  removing  and  installing , checking  nominal  parameters  of  apparatus  supplied . My  responsibilities  were  and  intervention  in  the  internal  and  external  lighting  installations , checking  and  changing  sockets  defective  , interventions  precious  painting  voltage    of  8kV  works  in  cells  , replacing  damaged  sockets  and  fuse  power  and  control .In  the  work  program  revisions  made   electric  motors  o,75 kW , 1,1 kW  , 4 kW , 5,5 kW , 7kW, 11 kW , 15 kW , 22 kW ,35 kW , 100 kW , 250 kW , voltage  transformers  decending  and lifts  and  various  ellectricaly  operated  gears .The  Romanian  company  I  worked   as  an  electrician  on  various  construction  and  assembly  ,  works  for  routes  pipe  pvc  or  conduit  mounting  ,    mounting  devices  ,  switches , plugs  , lamps , sensors  , wiring  drawings , cable  routes constructions , installation  of  electric  motors ,  switches  signaling  station  batteries . I  the  instrumentation  cable  to  power  pulled  from  instrumentation  panels  from  the  general  area  ,  we  installed  sensor  pressure  ,  sensor  of  temperature ,  valves , solenoid , gauge  class  , freeze  sensor , meters  from  electricity , water , gas , smoke  vents , ventilation  fans.

Education

  • 1983 - 1987

    Highschool, LICEUL INDUSTRIAL NR2 BOTOSANI

    • Botoșani, Romania

Foreign languages

English
Intermediate
French
Intermediate
Italian
Beginner
Russian
Beginner
Romanian
Native